Machine data
- Burckhardt compressor (2BX2XC1)
- 2 Cylinder / Double acting
- Suction pressure: 13,5 bar
- Discharge pressure: 32 bar
- Piston stroke: 250 mm
- Rotation speed: const. 370 U/min
- Drive: Electric drive
- Machine power: 631 kW
- Gas: Hydrogen H2
Monitoring equipment

Summary
Alert & Shutdown on Motor Shaft
Findings by PROGNOST
- Motor Shaft movement increased within a few minutes on both probes (real signals)
- Cylinder 1 & 2: Signals are close to “normal“
- Vibration Frame X/Y: Increased
Recommendation (Literally):
“In my opinion the problem is caused in the area of the motor. It is recommended to check the motor and not to restart the machine.”


Findings
- Displacement of flange
- Sealing rings touched the axis
- Higher vibration
- Higher temperature
- (Sealing-) metal touched the axis





Conclusion
- Safety/Shutdown messages were correct
- Recommended maintenance was correct
- Analyze showed:
- Real signals
- Only in area of motor
- Analyze showed:
- Customer repaired/exchanged the parts and restarted the machine without any further damage