Technical Description
data acquisition
| Measurement parameters / signals | Monitored Machine Parts |
|---|---|
| Vibration (acceleration) | Crosshead Cylinder Bearing Housing |
| Vibration (velocity) | Housing Bearing Piping |
| Dynamic pressures | Compression chamber Suction/Discharge pressures Piping |
| Temperatures | Bearing Gas, Liquids Valve etc. |
| Dynamic position (Displacement) | Piston rod position Plunger position Shaft vibration Axial thrust |
| Indirect pressure measurement | Strain gauge etc. |
| Phase reference | Piston rod |
General technical data of the data acquisition cards
• Four intrinsically safe inputs EEx ia IIC T4, Class 1, Division 2, according to ATEX, FM, CSA
• Galvanic separation of each input channel
• Sampling rate = 25 kHz
• DSP technology
• Self test
• Failure detection open circuit
• Failure detection short circuit
• Failure detection measurement range or with TI1 redundancy test
• Failure detection voltage supply
Downloads: